Thermal store or unvented cylinder: which is better?

  • Thermal Stores
  • 3 min read
  • Updated 7th October, 2026
answer

It depends on the system. A thermal store gives mains pressure hot water without the metal G3 discharge pipework, pressure reducing set and relief valves that an unvented cylinder needs, and it can take more than one heat source, such as a boiler, a wood burner and solar. With a heat pump, an unvented heat pump cylinder is the better choice, because thermal stores run hotter than a heat pump can usually supply.

How they differ

Both give you hot water at mains pressure, but they do it in different ways. An unvented cylinder stores your domestic hot water under mains pressure. A vented thermal store keeps its stored water at atmospheric pressure and heats mains water as it flows through a coil inside the store. Most of the practical differences come from that.

Safety equipment and installation

Because an unvented cylinder holds hot water under pressure, Part G3 of the Building Regulations requires safety devices that stop the stored water going above 100°C, and pipework that carries any discharge safely away. It must also be fitted by someone qualified to install unvented systems. See Approved Document G on GOV.UK.

A vented thermal store avoids that equipment. The Advance ECO ETS, for example, needs no relief valves, tundish or metal discharge pipe. A vented store also has no pressure reducing set; Advance only asks for a 3 bar control valve where the mains pressure is likely to go above 3 bar.

Flow rate

With a good mains supply, an Advance thermal store gives 20 to 30 litres of hot water a minute. The Advance Appliances installation guide recommends at least 2 bar through a 22mm pipe and a flow above 18 litres a minute. You can check your own supply with a bucket and a stopwatch.

More than one heat source

A thermal store can take several heat sources at once. The Advance SFUTS multi fuel thermal store links gas or oil boilers, wood burners, solar thermal or solar PV and electric immersion heaters, each with its own thermostat. It works as a sealed system up to 3 bar, so it also suits underfloor heating.

When an unvented cylinder is the better choice

With a heat pump. A thermal store runs at about 75°C, which is hotter than a heat pump normally supplies. For heat pumps, Advance makes unvented heat pump cylinders with large, low resistance coils. A heat pump can feed a multi fuel store only if a boiler tops the store up to 75°C.

Looking after it

Advance recommends servicing its thermal stores every year: check the shock arrestor charge, rinse the blending valve filters and keep the inhibitor topped up.

key takeaways
  • Both give mains pressure hot water; a vented thermal store does it without storing domestic water under pressure.
  • Vented thermal stores avoid the G3 discharge pipework and relief valves an unvented cylinder needs.
  • A thermal store can link several heat sources, including wood burners and solar.
  • With a heat pump, an unvented heat pump cylinder is the better choice.