Why heat pump hot water is cooler than boiler hot water
A heat pump works best at low flow temperatures. A 2013 laboratory study for the Department of Energy and Climate Change found that low heat pump flow temperatures and low cylinder storage temperatures give the best system efficiency. A gas or oil boiler can heat a cylinder hotter, but a heat pump on its own usually brings an Advance Appliances heat pump cylinder to around 50°C.
The coil decides how much of the heat pump's output gets into the water. Advance rates its coil outputs at typical heat pump flow rates and temperatures, so the published figures match how the cylinder will be used.
Why the cylinder still needs to reach 60°C
Health and Safety Executive (HSE) guidance asks for stored hot water to be held at 60°C or higher and distributed at 50°C or higher, to control legionella. A heat pump on its own falls short of the storage figure, so the cylinder needs a regular high temperature cycle; see how a heat pump cylinder deals with legionella.
Lower temperatures have an upside in hard water areas. The Advance installation guide notes that cooler water deposits less scale.
The immersion heater can take it to 60°C
- Every Advance heat pump cylinder has at least one 3kW immersion heater, and the installation guide says its thermostat must be set to 60°C.
- If the hot water runs cool, the guide says you may need to switch the immersion on manually.
- The ECO 200, 250 and 300 litre models have two immersion heaters, so one can run from solar PV.
- Advance sells an immersion control plug in stat for heat pump cylinders and buffer stores.
Keeping the temperature steady
Scale on the immersion elements cuts their performance. Where a water softener is fitted, Advance says it should handle flows of about 50 litres a minute. Without a softener or descaler, the elements need descaling from time to time.
Advance asks for an annual service by a competent unvented installer. One of the checks is that the controls do not let water reach the taps above 60°C.
For sizing, read what size heat pump cylinder do I need or browse the ECO heat pump cylinder range.
- From a heat pump alone, expect hot water at around 50°C, sometimes a little more.
- Low flow and storage temperatures give the best heat pump efficiency, according to a study for DECC.
- HSE guidance asks for stored hot water to reach 60°C, so the cylinder needs a regular high temperature cycle.
- The cylinder's 3kW immersion heater, set to 60°C, can raise the temperature when needed.
- Cooler stored water deposits less scale in hard water areas.
Managing Director, Advance Appliances. 20+ Years experience