 Why unvented?  

 No tanks in the loft
 •
Site anywhere in the property
 •
Mains pressure hot water
 • Power shower
without a pump
 • Can fill a standard bath in only a
few minutes
 • Familiar to
UK installers
 •
WRAS approved
 •
Lightweight and long life stainless steel     construction

 
   
unvented hot water systems
 
 
 What type do I need ?
Direct for electric homes
Indirect for oil/gas boilers
 
Storage Capacity (litres) 90 125 150 170 200 250 300
Overall diameter (mm) 520 520 520 520 520 520 520
Overall diameter inc. immers heater (mm) 605 605 605 605 605 605 605
Overall height with exp. vessel
on cold feed supply (mm)
755 980 1105 1255 1455 1755 2065
Overall height with exp. vessel on top (mm) (G) 1083 1308 1433 1583 1816 - -
Prim flow/return connect (mm) (B/C) 22 22 22 22 22 22 22
Cold feed/hot draw off connections (mm) (D/E) 22 22 22 22 22 22 28
Max water supply pressure (bar) 12 12 12 12 12 12 12
System operating pressure (pre-set) (bar) 3 3 3 3 3 3 3
Expansion vessel charge pressure (bar) 3 3 3 3 3 3 3
Expansion relief valve set pressure (bar) 6 6 6 6 6 6 6
Temp & pressure relief valve set
lift pressure (bar) (F)
7 7 7 7 7 7 7
Lift Temp (°C) 90 90 90 90 90 90 90
Max primary working pressure (bar) 3 3 3 3 3 3 3
Immersion heater(s) (A)

Indirect 90-250 x 1
Indirect 300 x 2
Direct x 2

  All dimensions are in mm from baseline
 
 
 What size do I need ?
Direct (electric) Size
One Shower 90
Single bath - 2 bedroom 125
Single bath - 3 bedroom 150
Single bath and shower 170
Twin bath 200
Twin bath and shower 250
Three bath 300
Indirect (gas/oil/boiler) Size
Single bath 90
Single bath and shower 125
Twin bath 150
Twin bath and shower 170
Twin bath and 2 shower 200
Three bath and two shower 250
Three bath and 3 shower 300
 
 
Performance 90 125 150 170 200 250 300
Heat up 15 to 65°C
for indirect cylinder (min)
26 36 37 36 33 35 40
Heat up 15 to 65°C
for direct cylinder (min)
52 72 86 98 108 144 202
Reheat 70% of contents for
indirect cylinder (min)
18 25 26 25 24 25 29
Reheat 70% of contents for
direct cylinder (min)
27 37 45 51 63 75 136
Heat Loss kWhr/24hrs 1.07 1.35 1.61 1.72 1.78 1.97 2.32
 
 
 Installing & Maintenance

The installation process will be straightforward to the competent installer.

The units are designed to fit within a standard UK airing cupboard of 600mm square. All connections are front facing to make servicing simple.

The units can go anywhere within the property, and the kit supplied is comprehensive.

Service the units every year to maintain warranties, details are found in the log book supplied with each unit.

 What comes with each unit?
Fitted to the unit is a pressure and temperature relief valve.
Supplied with the unit are immersion heater(s), expansion vessel, expansion valve, pressure reducing valve, tun dish, check valve and for indirect units a two port motorised valve and dual control probe type thermostat.
 
   Approvals and Warranties
 
WRAS approval number 0607103
Warranty 25 years on the tank. 1 year on components, subject to terms and conditions.
   
   
 
 
   
Advance
Appliances Ltd

Unit 4
Coppice Side Ind Est
Brownhills
Walsall
West Midlands
WS8 7EX

Tel: 01543 377723
Fax: 01543 360620
 
 
home | unvented hot water systems | solar hot water systems | electric thermal store systems | electric/solar boiler
gas or oil thermal store systems | bespoke hot water products | latest news | installation guides | contact us
design by nutcracker